Skip to content

Flow Measurement in a Biomass Power Station

Reliable Monitoring for Energy Utilities

How can flow measurement in a large-scale power station be reliably verified without disrupting ongoing operations? At the Amercentrale biomass power station in the Netherlands, portable KATflow 200 clamp-on ultrasonic flowmeters were used to meet this challenge. Despite large pipe diameters, heavily corroded steel pipework and water containing suspended solids, accurate, reliable and repeatable measurement results were achieved. One particular challenge was meeting the plant operator's requirement for a maximum measurement uncertainty of just 1%.

Measurement Task and Requirements

Liquid flows are an essential part of power generation. Whether handling fuel oil, demineralised water or seawater, reliable flow monitoring is critical to the safe and efficient operation of power stations and combined heat and power (CHP) plants.

In many power generation facilities, permanently installed flowmeters have been in operation since the plant was first commissioned. However, as equipment ages, these meters may lose accuracy or fail completely. Replacing a conventional inline flowmeter involves considerable effort: the affected pipeline must be shut down, drained and made accessible for installation. This not only increases costs and labour requirements but can also result in unwanted plant downtime. In particularly sensitive facilities, such as nuclear power stations, carrying out such an intervention may even be practically impossible.

Amercentrale in Geertruidenberg, the Netherlands, faced a similar challenge. Operated by RWE, the facility is one of Europe's largest biomass power stations and has been running entirely on sustainable biomass, primarily wood pellets, since early 2025.

As part of a project carried out by Katronic's Benelux distribution partner, U-F-M (Ultrasonic Flow Management), flow measurements were required on large-diameter steel pipelines. The conditions were challenging: the pipes had a diameter of 900 mm (35.4 inches) and showed extensive corrosion. In addition, the water being measured contained suspended solid particles. Another key requirement specified by the plant operator was a maximum measurement uncertainty of 1%. A solution was therefore needed that could deliver reliable and repeatable results even under these difficult conditions, preferably without interfering with ongoing plant operations.

Project Specifications at a Glance

  • Industry: Power Generation, Biomass Power Plant
  • Flowmeter: KATflow 200
  • Installation type: Portable
  • Medium: Water containing solid particles
  • Pipe material: Steel, heavily corroded
  • Pipe diameter: 900 mm
  • Special feature: Measurement uncertainty 1 % required

Technical Solution

The portable KATflow 200 ultrasonic flowmeter was selected for this application. The device allows flexible installation on existing pipework, making it particularly suitable for applications where replacing permanently installed meters would involve significant effort or operational risks. One of its key advantages is its portability. Since the device can be easily moved between different measurement locations, it is ideal for checking multiple pipelines throughout a power station. A single flowmeter can therefore be used to collect data at several measurement points, eliminating the need to install separate stationary instrumentation at each location. The KATflow 200 thus provides a flexible solution for recurring verification measurements and checking different flow measurement points without modifying or interrupting the existing pipework.

Methodology and Results

Measurements at Amercentrale were performed by Katronic's partner U-F-M using the portable KATflow 200. Despite the large pipe diameter of 900 mm (35.4 inches), the heavily corroded steel surfaces and the presence of suspended solids in the water, satisfactory measurement results were achieved. The plant operator was particularly satisfied with the accuracy, reliability and repeatability of the measurements. This demonstrated that clamp-on ultrasonic technology can deliver reliable results even under demanding conditions in the power generation industry. The KATflow 200 therefore offers a practical and cost-effective solution for challenging flow measurement applications in power generation, particularly where operational safety, measurement reliability and minimal disruption during installation are key priorities.

Advantages of the Measurement Technology Used

Katronic measuring instruments enable reliable flow measurements under a wide variety of conditions. Find out what technical features the KATflow 200 flowmeter offers to meet the customer’s specific requirements in this application:

Simple, Quick and Cost-Effective

installation on existing pipework

 

Simultaneous Measurement of Several Pipes

thanks to multi-channel devices

Measurement of a Wide Variety of Media

including non-conductive liquids, such as demineralised water and fuels

Versatile

on pipes made from a wide variety of materials, including duplex stainless steel

 

Retrofitting

also possible on radioactive water pipes

Easy Integration

into existing or future control and monitoring systems

Image credit: U-F-M 

Privacy settings

We use several types of cookies and integrations on this website to provide you with an optimal online experience, to increase the user-friendliness of our portal and to constantly improve our communication with you. You can decide which categories you want to allow and which you do not want to allow (see "Custom settings" for more information).

Cookies

Name Usage Duration
privacylayerStatus Agreement Cookie hint1 year
PHPSESSIDIdentification of current sessionEnd of session
ds-accessibilityKontrast erhöhen7 Tage
ds-animationsAnimationen deaktivieren7 Tage

Cookies

Name Usage Duration
_gaUser identification2 years
_gidUser identification1 day
_gatGoogle Analytics1 minute
_galiGoogle Analytics30 seconds
_ga_CONTAINER-I:fearfulcSession identificationEnd of session
_gac_gb_CONTAINER-I:fearfulcContains information about campaigns and is then read by Google Ads

Integrations

Name Usage
youtubeYoutube video embedding
vimeoVimeo video embedding